  "name": "Ukraine Electrical Substation Cyber Warfare Blackout - ATT&CK Navigator Layer",
  "versions": {
    "attack": "15",
    "navigator": "4.5",
    "layer": "4.5"
  },
  "domain": "enterprise-attack",
  "description": "MITRE ATT&CK technique mappings with verified legal evidence for case ukraine-power-grid-blackout-sandworm.",
  "filters": {
    "platforms": [
      "Windows",
      "Linux",
      "macOS",
      "Network",
      "PRE"
    ]
  },
  "sorting": 0,
  "layout": {
    "layout": "side",
    "aggregateFunction": "average",
    "showID": true,
    "showName": true,
    "showAggregateScores": false,
    "countUnscored": false
  },
  "hideDisabled": false,
  "techniques": [
    {
      "techniqueID": "T1566.001",
      "score": 1,
      "color": "#f59e0b",
      "comment": "Operatives sent spearphishing emails with malicious Microsoft Office attachments containing BlackEnergy 3 macros to utility administrative personnel.",
      "enabled": true,
      "metadata": [
        {
          "name": "locator",
          "value": "CISA Alert IR-ALERT-H-16-056-01"
        },
        {
          "name": "status",
          "value": "reviewed"
        }
      ]
    },
    {
      "techniqueID": "T1078",
      "score": 1,
      "color": "#f59e0b",
      "comment": "Conspirators hijacked legitimate Virtual Private Network (VPN) credentials connecting corporate IT networks to the isolated Industrial Control System (ICS) network.",
      "enabled": true,
      "metadata": [
        {
          "name": "locator",
          "value": "DOJ Indictment \u00b6 55, Page 37"
        },
        {
          "name": "status",
          "value": "reviewed"
        }
      ]
    },
    {
      "techniqueID": "T1485",
      "score": 1,
      "color": "#f59e0b",
      "comment": "Operators deployed the KillDisk wiper utility, overwriting master boot records and systematically destroying operator workstation files to inhibit grid restoration.",
      "enabled": true,
      "metadata": [
        {
          "name": "locator",
          "value": "CISA Alert IR-ALERT-H-16-056-01"
        },
        {
          "name": "status",
          "value": "reviewed"
        }
      ]
    }
  ],
  "gradient": {
    "colors": [
      "#0e1420",
      "#f59e0b"
    ],
    "minValue": 0,
    "maxValue": 1
  },
  "legendItems": [
    {
      "label": "Mapped in primary evidence",
      "color": "#f59e0b"
    }
  ],
  "metadata": [
    {
      "name": "case_slug",
      "value": "ukraine-power-grid-blackout-sandworm"
    },
    {
      "name": "case_title",
      "value": "Ukraine Electrical Substation Cyber Warfare Blackout"
    }
  ]
}